顶部链接&语言切换

Time of issue:2021-09-16 17:43:45

Home  |  About us  |  Products  |  News  | Resoures  |  Careers  |  Contact us        CNEN

imgboxbg

Products

cTnI/CK-MB/MYO Quantitative Test Kit (TRFIA)
1/1
Number of views:
1000
The simultaneous detection of three markers (cTnI / CK-MB / myo) can diagnose patients with myocardial infarction more sensitively, specifically and quickly, so as to early diagnose and treat the patients, and reduce risk of missed diagnosis.
Number of views:
1000
Product serial number
Quantity
-
+
1
General Info
Video
产品详细右侧内容:

The simultaneous detection of three markers (cTnI / CK-MB / myo) can diagnose patients with myocardial infarction more sensitively, specifically and quickly, so as to early diagnose and treat the patients, and reduce risk of missed diagnosis.

Intended Use

This cTnI/CK-MB/MYO Test Kit (Time Resolved Fluorescence Immunochromatographic Assay) is suitable for quantitative detection of cardiac troponin I, creatine kinase isoenzyme and myoglobin in human serum/plasma /whole blood in vitro.

For Medical Professional Use Only!

Product Information

Production name

Test samples

Specifications

cTnI/CK-MB/MYO Quantitative Test Kit (TRFIA)

serum/plasma/whole blood 

20T/Kit, 50T/Kit

 

Storage Conditions and Expiry Date

The unopened kit was stored in 2℃~8℃ for 18 months. The product can be stored at temperature (20℃~30℃) for 30 days if expiry printed on the package is not exceeded. The temperature change during transportation (<37℃) has no effect on product quality. The reagent strip and the sample buffer are used in one-to-one mode, that is, a reagent strip is matched with a sample buffer to detect a blood sample.After unsealing, it can be stabilized for 1 hour at room temperature. Under normal humidity and light conditions, store and use according to the above requirements.

 

Product Performance

Accuracy: the relative deviation from the target value should be within 15%.

Limit of detection:cTnI ≤0.05 ng/ml, CK-MB≤0.5 ng/ml,MYO≤20 ng/ml.

Linearity range: The regression coefficient(r≥0.9900) should be detected in samples(cTnI:[0.1~20]ng/ml, CK-MB:[1~50] ng/ml, MYO: [25~300] ng/ml).

Repeatability: coefficient of variation(CV)is no more than 15%.

Inter-batch difference: coefficient of variation between batches(CV)is no more than 15%

We could not find any corresponding parameters, please add them to the properties table