Products
Creatinine Test Strips (Dry chemical method) is suitable for quantitative determination of creatinine concentration in whole blood or serum in vitro.
Creatinine is the metabolic end product of creatine phosphate in human muscles, which is mainly cleared through glomerular fifiltration. Under normal circumstances, the serum creatinine level in human body remains basically stable. When the kidneys are damaged, the normal excretion of creatinine in body is blocked, and serum creatinine levels are elevated. Therefore, serum creatinine concentration can reflflect the glomerular fifiltration rate. It is clinically used as a routine item for the monitoring and analyzing of renal function.
Intended Use
Creatinine Test Strips (Dry chemical method) is suitable for quantitative determination of creatinine concentration in whole blood or serum in vitro.
Creatinine is the metabolic end product of creatine phosphate in human muscles, which is mainly cleared through glomerular fifiltration. Under normal circumstances, the serum creatinine level in human body remains basically stable. When the kidneys are damaged, the normal excretion of creatinine in body is blocked, and serum creatinine levels are elevated. Therefore, serum creatinine concentration can reflflect the glomerular fifiltration rate. It is clinically used as a routine item for the monitoring and analyzing of renal function. At present, there are enzymatic methods and chemiluminescence methods commonly used to detect creatinine content in blood samples.
Product Information
Production name |
Test samples |
Specifications |
Creatinine test strips (Dry chemical method) |
whole blood or serum samples |
15 tests/ kit, 50 tests/ kit |
Storage Conditions and Expiry Date
All reagents are ready to use as supplied.
For Aluminum foil bag package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively. Please use the test strip within 1 hour once the foil bag is open.
For cylinder package: unopened reagent kits are stable at 4°C ~30°C for 18 months tentatively.the test strips in cylinder are stable at 4°C ~30°C for 30 days tentatively once the cylinder package is opened.
Test Procedure
1. Read the instruction carefully before use.
2. Insert the IC card that matches the lot number on the test strips.
3. Take out the test strip from the aluminum foil bag or drying cylinder, insert it into the analyzer until the end cannot go any further.
4. When ‘ADD SAMPLE’ appears on the display, use a capillary blood collector or pipet to apply 20μL of whole blood or serum sample to the test strip sample application window.
5. In about 4 minutes, the results will appear on the display automatically on the analyzer.
6. Calibrator and quality control instructions: The test strip adopts IC card calibration mode, and the analyzer automatically reads batch-specifific calibration data from the IC card without user calibration.
7. Take out and discard the test strip. The test strip is for one-time use only. Do not use it again.